{"id":4115,"date":"2021-07-26T00:10:19","date_gmt":"2021-07-25T17:10:19","guid":{"rendered":"https:\/\/gmpgroups.com.vn\/product\/tu-an-toan-sinh-hoc\/"},"modified":"2022-03-04T20:29:41","modified_gmt":"2022-03-04T13:29:41","slug":"biosecurity-cabinet","status":"publish","type":"mona_product","link":"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/","title":{"rendered":"Biosecurity Cabinet"},"content":{"rendered":"<h2><span style=\"font-size: 24px; color: #253d8f;\"><strong>What is a biosecurity cabinet?<\/strong><\/span><\/h2>\n<p><span style=\"font-size: 20px;\">A BioSafety Cabinet is a closed, convection cabinet that protects the manipulator, environment and sample from biologically infectious agents.<\/span><\/p>\n<p><span style=\"font-size: 20px;\">According to NSF\/ANSI 49 standards of the U.S. Centers for Disease Control and Prevention (CDC), biosecurity cabinets are divided into three levels: Level I (Class I), Grade II (Class II) and Grade III (Class III).<\/span><\/p>\n<h3><span style=\"color: #253d8f; font-size: 24px;\"><strong>Biosecurity Cabinet Classification<\/strong><\/span><\/h3>\n<p><span style=\"font-weight: 400; color: #000000; font-size: 20px;\">Biosecurity cabinet standards comparison table based on U.S. NFS 49 technical standard:<\/span><\/p>\n<p><span style=\"color: #000000; font-size: 20px;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1875\" src=\"http:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/bang-so-sanh-tieu-chuan-tu-an-toan-sinh-hoc.png\" alt=\"B\u1ea3ng so s\u00e1nh ti\u00eau chu\u1ea9n t\u1ee7 an to\u00e0n sinh h\u1ecdc\" width=\"929\" height=\"730\" srcset=\"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/bang-so-sanh-tieu-chuan-tu-an-toan-sinh-hoc.png 929w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/bang-so-sanh-tieu-chuan-tu-an-toan-sinh-hoc-300x236.png 300w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/bang-so-sanh-tieu-chuan-tu-an-toan-sinh-hoc-768x603.png 768w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/bang-so-sanh-tieu-chuan-tu-an-toan-sinh-hoc-636x500.png 636w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/bang-so-sanh-tieu-chuan-tu-an-toan-sinh-hoc-675x530.png 675w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/bang-so-sanh-tieu-chuan-tu-an-toan-sinh-hoc-560x440.png 560w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/bang-so-sanh-tieu-chuan-tu-an-toan-sinh-hoc-191x150.png 191w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/bang-so-sanh-tieu-chuan-tu-an-toan-sinh-hoc-660x519.png 660w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/bang-so-sanh-tieu-chuan-tu-an-toan-sinh-hoc-573x450.png 573w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/bang-so-sanh-tieu-chuan-tu-an-toan-sinh-hoc-354x278.png 354w\" sizes=\"auto, (max-width: 929px) 100vw, 929px\" \/><\/span><\/p>\n<p><span style=\"color: #000000; font-size: 20px;\"><span style=\"color: #253d8f;\"><b>Grade I Biosecurity Cabinets (Class I)<\/b><\/span><span style=\"font-weight: 400;\">: has the ability to protect employees and the surrounding environment from infectious agents, incapable of protecting the sample. The Grade I cabinet has a similar airflow to a chemical intake cabinet but has HEPA filter at the top of the gas to prevent harmful agents from spreading into the environment. This type of cabinet is currently rarely used.<\/span><\/span><\/p>\n<p><span style=\"color: #000000; font-size: 20px;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1876\" src=\"http:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/11.-tu-an-toan-sinh-hoc-cap-1.png\" alt=\"t\u1ee7 an to\u00e0n sinh h\u1ecdc c\u1ea5p 1\" width=\"470\" height=\"400\" srcset=\"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/11.-tu-an-toan-sinh-hoc-cap-1.png 470w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/11.-tu-an-toan-sinh-hoc-cap-1-300x255.png 300w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/11.-tu-an-toan-sinh-hoc-cap-1-176x150.png 176w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/11.-tu-an-toan-sinh-hoc-cap-1-354x301.png 354w\" sizes=\"auto, (max-width: 470px) 100vw, 470px\" \/><\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"color: #000000; font-size: 20px;\"><em>T\u1ee7 an to\u00e0n sinh h\u1ecdc c\u1ea5p I<\/em><\/span><\/p>\n<p><span style=\"color: #000000; font-size: 20px;\"><span style=\"color: #253d8f;\"><b>Grade II Biosecurity Cabinets (Class II)<\/b><\/span><span style=\"font-weight: 400;\"><span style=\"color: #253d8f;\">:<\/span> The flow of air in and out of the cabinet passes through the HEPA filter so the cabinet has the ability to protect both the operation staff, the surroundings and specimens. Grade II biosecurity cabinets are also classified into four smaller categories: A1, A2, B1 and B2.\u00a0<\/span><\/span><\/p>\n<p><span style=\"color: #000000; font-size: 20px;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1877\" src=\"http:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/12.-tu-an-toan-sinh-hoc-cap-2.png\" alt=\"T\u1ee7 an to\u00e0n sinh h\u1ecdc c\u1ea5p II\" width=\"439\" height=\"400\" srcset=\"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/12.-tu-an-toan-sinh-hoc-cap-2.png 439w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/12.-tu-an-toan-sinh-hoc-cap-2-300x273.png 300w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/12.-tu-an-toan-sinh-hoc-cap-2-165x150.png 165w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/12.-tu-an-toan-sinh-hoc-cap-2-354x323.png 354w\" sizes=\"auto, (max-width: 439px) 100vw, 439px\" \/><\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"color: #000000; font-size: 20px;\"><em>T\u1ee7 an to\u00e0n sinh h\u1ecdc c\u1ea5p II<\/em><\/span><\/p>\n<p><span style=\"color: #253d8f; font-size: 20px;\"><b>Grade III Biosecurity Cabinets (Class III)<\/b><\/span><\/p>\n<p><span style=\"color: #000000; font-size: 20px;\"><span style=\"font-weight: 400;\">This type of cabinet provides absolute safety protection for the user; surroundings and specimens. The cabinet is fully enclosed, ventilated through the HEPA filter. Cabinets are equipped with glove gates and sample ports with Pass-boxes or 2-door sterilization equipment. Level 3 safety cabinets are used with manipulation samples with high risk of disease, easy to spread, harmful bacteria and viruses.<\/span><\/span><\/p>\n<p><span style=\"color: #000000; font-size: 20px;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1878\" src=\"http:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/13.-tu-an-toan-sinh-hoc-cap-3.png\" alt=\"T\u1ee7 an to\u00e0n sinh h\u1ecdc c\u1ea5p III\" width=\"463\" height=\"400\" srcset=\"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/13.-tu-an-toan-sinh-hoc-cap-3.png 463w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/13.-tu-an-toan-sinh-hoc-cap-3-300x259.png 300w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/13.-tu-an-toan-sinh-hoc-cap-3-174x150.png 174w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/13.-tu-an-toan-sinh-hoc-cap-3-354x306.png 354w\" sizes=\"auto, (max-width: 463px) 100vw, 463px\" \/><\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"color: #000000; font-size: 20px;\"><em>T\u1ee7 an to\u00e0n sinh h\u1ecdc c\u1ea5p III<\/em><\/span><\/p>\n<h2><span style=\"font-size: 24px; color: #253d8f;\"><strong>Distinguishing biosecurity cabinets and microbiological implant cabinets<\/strong><\/span><\/h2>\n<p><span style=\"font-size: 20px;\">Although shaped like a Biosecurity Cabinet, the microbiological implant cabinet does not protect the manipulator and the surrounding environment. The task of the Microbiological Implant Cabinet is to protect the specimen. This device is often used in experiments with non-harmful bacteria; culture of plant and animal tissue, PCR operation; or manipulate semiconductors, microchips.<\/span><\/p>\n<p><span style=\"font-size: 20px;\">Attention should be paid to avoiding confusion. Microbiological implants must not be used to manipulate biological agents or hazardous materials.<\/span><\/p>\n<p><span style=\"color: #000000; font-size: 20px;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1879\" src=\"http:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/14.-tu-cay-vi-sinh.jpg\" alt=\"T\u1ee7 c\u1ea5y vi sinh\" width=\"290\" height=\"300\" srcset=\"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/14.-tu-cay-vi-sinh.jpg 290w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/14.-tu-cay-vi-sinh-24x24.jpg 24w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/14.-tu-cay-vi-sinh-28x28.jpg 28w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/14.-tu-cay-vi-sinh-32x32.jpg 32w, https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/14.-tu-cay-vi-sinh-145x150.jpg 145w\" sizes=\"auto, (max-width: 290px) 100vw, 290px\" \/><\/span><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A BioSafety Cabinet is a closed, convection cabinet that protects the manipulator, environment and sample from biologically infectious agents.<\/p>\n","protected":false},"author":1,"featured_media":3961,"comment_status":"open","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"class_list":["post-4115","mona_product","type-mona_product","status-publish","has-post-thumbnail","hentry","category_product-biosecurity-cabinet"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Biosecurity Cabinet - GMP Groups<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Biosecurity Cabinet - GMP Groups\" \/>\n<meta property=\"og:description\" content=\"A BioSafety Cabinet is a closed, convection cabinet that protects the manipulator, environment and sample from biologically infectious agents.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/\" \/>\n<meta property=\"og:site_name\" content=\"T\u01b0 v\u1ea5n thi\u1ebft k\u1ebf thi c\u00f4ng ph\u00f2ng s\u1ea1ch \u0111\u1ea1t chu\u1ea9n GMP v\u00e0 ISO | GMP GROUPS\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/gmpgroups\" \/>\n<meta property=\"article:modified_time\" content=\"2022-03-04T13:29:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/tu-an-toan-sinh-hoc-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"533\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/\",\"url\":\"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/\",\"name\":\"Biosecurity Cabinet - GMP Groups\",\"isPartOf\":{\"@id\":\"https:\/\/gmpgroups.com.vn\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/tu-an-toan-sinh-hoc-2.jpg\",\"datePublished\":\"2021-07-25T17:10:19+00:00\",\"dateModified\":\"2022-03-04T13:29:41+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/#breadcrumb\"},\"inLanguage\":\"en\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/#primaryimage\",\"url\":\"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/tu-an-toan-sinh-hoc-2.jpg\",\"contentUrl\":\"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/tu-an-toan-sinh-hoc-2.jpg\",\"width\":700,\"height\":533,\"caption\":\"T\u1ee7 an to\u00e0n sinh h\u1ecdc\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/gmpgroups.com.vn\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"S\u1ea3n ph\u1ea9m\",\"item\":\"https:\/\/gmpgroups.com.vn\/product\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Biosecurity Cabinet\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/gmpgroups.com.vn\/#website\",\"url\":\"https:\/\/gmpgroups.com.vn\/\",\"name\":\"T\u01b0 v\u1ea5n thi\u1ebft k\u1ebf thi c\u00f4ng ph\u00f2ng s\u1ea1ch \u0111\u1ea1t chu\u1ea9n GMP v\u00e0 ISO | GMP GROUPS\",\"description\":\"V\u1edbi ph\u01b0\u01a1ng ch\u00e2m \u201cT\u1ed1i \u0111a h\u00f3a gi\u00e1 tr\u1ecb v\u00e0 l\u1ee3i \u00edch cho kh\u00e1ch h\u00e0ng\u201d, GMP Groups cam k\u1ebft kh\u00f4ng ng\u1eebng c\u1eadp nh\u1eadt c\u00e1c y\u00eau c\u1ea7u v\u1ec1 GMP\",\"publisher\":{\"@id\":\"https:\/\/gmpgroups.com.vn\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/gmpgroups.com.vn\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/gmpgroups.com.vn\/#organization\",\"name\":\"GMP Groups\",\"url\":\"https:\/\/gmpgroups.com.vn\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\/\/gmpgroups.com.vn\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/logo-header.png\",\"contentUrl\":\"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/logo-header.png\",\"width\":152,\"height\":50,\"caption\":\"GMP Groups\"},\"image\":{\"@id\":\"https:\/\/gmpgroups.com.vn\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/gmpgroups\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Biosecurity Cabinet - GMP Groups","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/","og_locale":"en_US","og_type":"article","og_title":"Biosecurity Cabinet - GMP Groups","og_description":"A BioSafety Cabinet is a closed, convection cabinet that protects the manipulator, environment and sample from biologically infectious agents.","og_url":"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/","og_site_name":"T\u01b0 v\u1ea5n thi\u1ebft k\u1ebf thi c\u00f4ng ph\u00f2ng s\u1ea1ch \u0111\u1ea1t chu\u1ea9n GMP v\u00e0 ISO | GMP GROUPS","article_publisher":"https:\/\/www.facebook.com\/gmpgroups","article_modified_time":"2022-03-04T13:29:41+00:00","og_image":[{"width":700,"height":533,"url":"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/tu-an-toan-sinh-hoc-2.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/","url":"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/","name":"Biosecurity Cabinet - GMP Groups","isPartOf":{"@id":"https:\/\/gmpgroups.com.vn\/#website"},"primaryImageOfPage":{"@id":"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/#primaryimage"},"image":{"@id":"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/#primaryimage"},"thumbnailUrl":"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/tu-an-toan-sinh-hoc-2.jpg","datePublished":"2021-07-25T17:10:19+00:00","dateModified":"2022-03-04T13:29:41+00:00","breadcrumb":{"@id":"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/#breadcrumb"},"inLanguage":"en","potentialAction":[{"@type":"ReadAction","target":["https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/"]}]},{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/#primaryimage","url":"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/tu-an-toan-sinh-hoc-2.jpg","contentUrl":"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/tu-an-toan-sinh-hoc-2.jpg","width":700,"height":533,"caption":"T\u1ee7 an to\u00e0n sinh h\u1ecdc"},{"@type":"BreadcrumbList","@id":"https:\/\/gmpgroups.com.vn\/en\/product\/biosecurity-cabinet\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/gmpgroups.com.vn\/en\/"},{"@type":"ListItem","position":2,"name":"S\u1ea3n ph\u1ea9m","item":"https:\/\/gmpgroups.com.vn\/product\/"},{"@type":"ListItem","position":3,"name":"Biosecurity Cabinet"}]},{"@type":"WebSite","@id":"https:\/\/gmpgroups.com.vn\/#website","url":"https:\/\/gmpgroups.com.vn\/","name":"T\u01b0 v\u1ea5n thi\u1ebft k\u1ebf thi c\u00f4ng ph\u00f2ng s\u1ea1ch \u0111\u1ea1t chu\u1ea9n GMP v\u00e0 ISO | GMP GROUPS","description":"V\u1edbi ph\u01b0\u01a1ng ch\u00e2m \u201cT\u1ed1i \u0111a h\u00f3a gi\u00e1 tr\u1ecb v\u00e0 l\u1ee3i \u00edch cho kh\u00e1ch h\u00e0ng\u201d, GMP Groups cam k\u1ebft kh\u00f4ng ng\u1eebng c\u1eadp nh\u1eadt c\u00e1c y\u00eau c\u1ea7u v\u1ec1 GMP","publisher":{"@id":"https:\/\/gmpgroups.com.vn\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/gmpgroups.com.vn\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en"},{"@type":"Organization","@id":"https:\/\/gmpgroups.com.vn\/#organization","name":"GMP Groups","url":"https:\/\/gmpgroups.com.vn\/","logo":{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/gmpgroups.com.vn\/#\/schema\/logo\/image\/","url":"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/logo-header.png","contentUrl":"https:\/\/gmpgroups.com.vn\/wp-content\/uploads\/2021\/07\/logo-header.png","width":152,"height":50,"caption":"GMP Groups"},"image":{"@id":"https:\/\/gmpgroups.com.vn\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/gmpgroups"]}]}},"_links":{"self":[{"href":"https:\/\/gmpgroups.com.vn\/en\/wp-json\/wp\/v2\/mona_product\/4115","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gmpgroups.com.vn\/en\/wp-json\/wp\/v2\/mona_product"}],"about":[{"href":"https:\/\/gmpgroups.com.vn\/en\/wp-json\/wp\/v2\/types\/mona_product"}],"author":[{"embeddable":true,"href":"https:\/\/gmpgroups.com.vn\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gmpgroups.com.vn\/en\/wp-json\/wp\/v2\/comments?post=4115"}],"version-history":[{"count":2,"href":"https:\/\/gmpgroups.com.vn\/en\/wp-json\/wp\/v2\/mona_product\/4115\/revisions"}],"predecessor-version":[{"id":4400,"href":"https:\/\/gmpgroups.com.vn\/en\/wp-json\/wp\/v2\/mona_product\/4115\/revisions\/4400"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gmpgroups.com.vn\/en\/wp-json\/wp\/v2\/media\/3961"}],"wp:attachment":[{"href":"https:\/\/gmpgroups.com.vn\/en\/wp-json\/wp\/v2\/media?parent=4115"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}